CAN
The ZSOM-Control and the ZSOM-Mini each provide one CAN (Controller Area Network) interface. It can be controlled from both FPGA and RT code; basic CANopen functions are available as RT VIs in the SDK.
Features
| ZSOM-Control | ZSOM-Mini | |
|---|---|---|
| Number of interfaces | 1 | 1 |
| Bit rate | classical high-speed CAN, up to 1 Mbit/s | classical high-speed CAN, up to 1 Mbit/s |
| Bus termination (120 Ω) | fitted on the board | fitted on the board |
| CANopen microcontroller on the bus | yes | no |
| Power | always on | requires GPIO ENVP, see Power and GPIOs |
| Terminals | CAN High 51, CAN Low 52, GND 50/53 (pinout) | CAN High 23, CAN Low 24, GND 22/25 (pinout) |
Bus termination
The termination is fitted on the board: split termination 2 × 62 Ω with 4.7 nF to GND (120 Ω between CAN High and CAN Low). A CAN bus must be terminated at both ends only, so the ZSOM must be placed at one end of the bus. If the ZSOM is not at one end of the bus, contact Schmid Elektronik.
Check: with all devices switched off, the resistance between CAN High and CAN Low of a correctly terminated bus is about 60 Ω.
Wiring
- Connect CAN High to CAN High and CAN Low to CAN Low of the other nodes. Use twisted-pair cable.
- Connect GND as reference between the nodes.
- All nodes on the bus must use the same bit rate.
CANopen microcontroller (ZSOM-Control)
The ZSOM-Control features a dedicated CANopen microcontroller. It is connected to the same CAN bus and via a digital interface directly to the FPGA. Its firmware must be flashed once with CAN_NXP_Firmwareupdate_RT_main.vi before the CAN examples can be used.
Usage in LabVIEW
The CAN interface of the sbRIO-9651 supports classical high-speed CAN only (no CAN FD). It is used with the NI Embedded CAN for RIO driver; NI-XNET is not supported. If the driver is not installed on the target, install it with NI MAX (see Installing Software on the ZSOM).
Examples
In the SDK you can find the following examples that show the basic CAN functionality:
- ZSOM-Control_CAN.lvproj
- **CAN_NXP_Firmwareupdate_RT_main.vi** flashes a binary file to the CANopen microcontroller on the ZSOM-Control. This is needed for the other examples to run.
- **CANraw_example.vi** requests a temperature value from the CANopen microcontroller using raw CAN frames. Because the microcontroller operates according to the CANopen standard, the commands are formatted accordingly.
- **CANopen_example.vi** requests the same temperature value using the CANopen VIs.
See also Trouble shooting (CAN bus errors, CAN examples do not work).