Switchable power supply
The switchable power supply of the ZSOM-Control provides a 5 V and a 3.3 V output that can each deliver up to 300 mA.
These outputs are intended to supply peripheral devices (e.g. sensors, small modules or external logic) whose supply voltage is switched on and off by the application running on the ZSOM-Control. Both outputs are current limited and short-circuit protected.
Features
| Parameter | +5V output | +3.3V output |
|---|---|---|
| Output current | up to 300 mA | up to 300 mA |
| Current limit | approx. 320 mA (typ.) | approx. 320 mA (typ.) |
| Protection | current limit, short circuit, over-temperature | current limit, short circuit, over-temperature |
| State after power-up / reset | off | off |
| Fault indication | yes, readable in the FPGA | yes, readable in the FPGA |
| Terminal (J9) | pin 47 | pin 49 |
| GND terminal | pin 48 | pin 50 |
See also the pinout.
Control signals
Each output is controlled by an enable signal and reports errors via a fault signal. The signals are available as FPGA I/O items in the CLIP of the ZSOM-Control:
| CLIP name | Direction | Polarity |
|---|---|---|
| GPIO_5VENB | Read/Write | TRUE = 5 V output on |
| GPIO_5VFAULT | Read-only | FALSE = fault (overcurrent or over-temperature) |
| GPIO_3VENB | Read/Write | TRUE = 3.3 V output on |
| GPIO_3VFAULT | Read-only | FALSE = fault (overcurrent or over-temperature) |
The enable inputs of the power switches have pull-down resistors, so both outputs stay off until the application switches them on.
Usage notes
- Switch the outputs on in your application after startup – they are off by default.
- If a fault is reported, switch the output off, remove the cause (e.g. short circuit or too high load) and switch it on again.
- The current drawn from these outputs adds to the power consumption of the ZSOM-Control. Make sure the power supply can deliver it.
- Do not feed an external voltage into these outputs.
- For loads above 300 mA, supply the peripheral directly from an external source.
The SDK example Example: DIO all shows how to switch the outputs on and off and how to read the fault signals.