Switchable power supply

The switchable power supply of the ZSOM-Control provides a 5 V and a 3.3 V output that can each deliver up to 300 mA.

These outputs are intended to supply peripheral devices (e.g. sensors, small modules or external logic) whose supply voltage is switched on and off by the application running on the ZSOM-Control. Both outputs are current limited and short-circuit protected.

Parameter +5V output +3.3V output
Output current up to 300 mA up to 300 mA
Current limit approx. 320 mA (typ.) approx. 320 mA (typ.)
Protection current limit, short circuit, over-temperature current limit, short circuit, over-temperature
State after power-up / reset off off
Fault indication yes, readable in the FPGA yes, readable in the FPGA
Terminal (J9) pin 47 pin 49
GND terminal pin 48 pin 50

See also the pinout.

Each output is controlled by an enable signal and reports errors via a fault signal. The signals are available as FPGA I/O items in the CLIP of the ZSOM-Control:

CLIP name Direction Polarity
GPIO_5VENB Read/Write TRUE = 5 V output on
GPIO_5VFAULT Read-only FALSE = fault (overcurrent or over-temperature)
GPIO_3VENB Read/Write TRUE = 3.3 V output on
GPIO_3VFAULT Read-only FALSE = fault (overcurrent or over-temperature)

The enable inputs of the power switches have pull-down resistors, so both outputs stay off until the application switches them on.

  • Switch the outputs on in your application after startup – they are off by default.
  • If a fault is reported, switch the output off, remove the cause (e.g. short circuit or too high load) and switch it on again.
  • The current drawn from these outputs adds to the power consumption of the ZSOM-Control. Make sure the power supply can deliver it.
  • Do not feed an external voltage into these outputs.
  • For loads above 300 mA, supply the peripheral directly from an external source.

The SDK example Example: DIO all shows how to switch the outputs on and off and how to read the fault signals.