Mounting
Fastening
ZSOM-Control and ZSOM-Mini are fastened with four screws each (M2.5 thread) on a flat surface. Dimensions and hole pattern see: ZSOM-Control, ZSOM-Mini.
Installation in a control cabinet
A simple solution is a metal plate: DIN rail adapters are fitted on one side, and the ZSOM module is screwed on the other side.
Cooling
- If possible, Mount the heat spreader (the plate printed with the Schmid logo) vertically so that air can flow past it.
- Alternatively, screw the heat spreader onto the enclosure wall.
- For optimal heat dissipation, replace the heat spreader with the enclosure wall itself. (ZSOM-Mini and custom built targets)
- The heat spreader can also be fitted or replaced with a heat sink.
Display
See Mounting the display.